Special characteristics of the three phase TLS inverters

  • 3 MPP trackers
  • up to 20,000 Wp recommended DC power
  • relay contact for self consumption optimisation
  • integrated data logger and web server
DC Input: BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Recommended DC power (+15 % acc. ISE) 15000 W 17000 W 20000 W
Maximum input voltage 1000 V 1000 V 1000 V
Minimum input voltage/Start input voltage Input A/(B): 250 V / 280 V Input A/(B): 250 V / 280 V Input A/(B): 250 V / 280 V
Minimum input voltage * Input C: 120 V Input C: 120 V Input C: 120 V
MPP voltage range 320-800 V 360-800 V 400-800 V
Rated input voltage 690 V 690 V 690 V
Maximum current per input (A/B) ** 18 A 18 A 18 A
Maximum short circuit current per input 20 A 20 A 20 A
Start feeding-in at 30 W 30 W 30 W
Number of independent MPP inputs 3 3 3
Strings per MPP input 2 2 2
DC terminal type SUNCLIX SUNCLIX SUNCLIX
DC Overvoltage category III III III
AC Output: BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Rated output power (230 V / 50 Hz, cos(φ)=1) 13000 W 15000 W 17000 W
Maximum apparent AC power 13000 VA 15000 VA 17000 VA
AC connection 3 / N / PE 3 / N / PE 3 / N / PE
AC nominal output voltage range 3 x 400 V / 3 x 230 V +/- 20 % 3 x 400 V / 3 x 230 V +/- 20 % 3 x 400 V / 3 x 230 V +/- 20 %
Power factor range, adjustable cos(φ) 0,9 ind. … 1 … 0,9 kap. 0,9 ind. … 1 … 0,9 kap. 0,9 ind. … 1 … 0,9 kap.
Operating range at nominal frequency 50 Hz 50 Hz / 47,5 Hz - 51,5 Hz 50 Hz / 47,5 Hz - 51,5 Hz 50 Hz / 47,5 Hz - 51,5 Hz
Maximum output current 3 x 22 A 3 x 22 A 3 x 25 A
Maximum short circuit current 3 x 22 A 3 x 22 A 3 x 25 A
Maximum permitted fusing Circuit breaker 32 A, characteristic B Circuit breaker 32 A, characteristic B Circuit breaker 32 A, characteristic B
Distortion factor at cos(φ) = 1 < 3 % < 3 % < 3 %
Self-consumption at night < 2 W < 2 W < 2 W
AC Overvoltage category III III III
Efficiency BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Maximum efficiency 98,0 % 98,0 % 98,0 %
European efficiency 97,5 % 97,5 % 97,5 %
Protection and protective devices: BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Topology transformerless transformerless transformerless
Protection class I I I
Earth fault detection integrated integrated integrated
Residual current monitoring integrated, sensitive to universal current integrated, sensitive to universal current integrated, sensitive to universal current
Overload behaviour operating point adjustment operating point adjustment operating point adjustment
Overtemperature behaviour operating point adjustment operating point adjustment operating point adjustment
Input isolator integrated integrated integrated
Overvoltage protection-input integrated, type 3 as per EN61643-11 integrated, type 3 as per EN61643-11 integrated, type 3 as per EN61643-11
Overvoltage protection-output integrated, type 3 as per EN61643-11 integrated, type 3 as per EN61643-11 integrated, type 3 as per EN61643-11
Automatic disconnection device as per VDE 0126-1-1 as per VDE 0126-1-1 as per VDE 0126-1-1
Environmental conditions BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Ingress protection IP 65 / connection area IP 54 IP 65 / connection area IP 54 IP 65 / connection area IP 54
Cooling concept variable speed, temperature-controlled fan variable speed, temperature-controlled fan variable speed, temperature-controlled fan
Operating temperature range -20°C – 60°C -20°C – 60°C -20°C – 60°C
Maximum ambient temperature at rated power 50°C 45°C 40°C
Climatic category 4K4H according to IEC 721-3-4 *** 4K4H according to IEC 721-3-4 *** 4K4H according to IEC 721-3-4 ***
Maximum operating altitude 2000 m above sea level 2000 m above sea level 2000 m above sea level
Noise emission ≤ 50 dB(A) ≤ 50 dB(A) ≤ 50 dB(A)
Standards and approvals BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
EMC emission EN 61000-6-3: 2007 EN 61000-6-3: 2007 EN 61000-6-3: 2007
EMC immunity EN 61000-6-2: 2005 EN 61000-6-2: 2005 EN 61000-6-2: 2005
Equipment safety EN 62109-1, -2 EN 62109-1, -2 EN 62109-1, -2
Grid compliance VDE-AR-N 4105, EN50438, AS4777, AS3100 VDE-AR-N 4105, EN50438, AS4777, AS3100 VDE-AR-N 4105, EN50438, AS4777, AS3100
General Data: BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Dimensions in mm (W x H x D) 455 x 612 x 213 mm (without plugs) 455 x 612 x 213 mm (without plugs) 455 x 612 x 213 mm (without plugs)
Weight (approx.) 45 kg 45 kg 45 kg
Features BENNING PV Inverter TLS 13.3 BENNING PV Inverter TLS 15.3 BENNING PV Inverter TLS 17.3
Display liquid crystal display, 128 x 64 pixel liquid crystal display, 128 x 64 pixel liquid crystal display, 128 x 64 pixel
Communication interfaces RS 485, USB, Ethernet, solar radiation, S0 as per DIN EN 62053-31 class B RS 485, USB, Ethernet, solar radiation, S0 as per DIN EN 62053-31 class B RS 485, USB, Ethernet, solar radiation, S0 as per DIN EN 62053-31 class B
Data storage 24 hours: 5-min values
30 days: hourly values
20 years: daily values
24 hours: 5-min values
30 days: hourly values
20 years: daily values
24 hours: 5-min values
30 days: hourly values
20 years: daily values
Relay contact potential-free contact 230 V / 2 A potential-free contact 230 V / 2 A potential-free contact 230 V / 2 A

*) This value is valid if one input has exceeded the start input voltage.
**) It is permitted to exceed this limit as long as the maximum short circuit current is not exceeded.
***) The device is designed for an outdoor use. Direct sunlight and precipitation (rain, snow hail) hast to be avoided on site.

Technical changes reserved, version of: 20.05.2014

Further Information

Brochures
Case Studies
Certificates
Data Sheets
Instruction manuals
Downloads

Technical Support
(After Sales Service)

Phone+49 2871 93 595
Email helpdesk@benning.de

Product Advice
Markus Gerwing

Phone+49 2871 93 120
Email m.gerwing@benning.de

Callback

Your contact persons

USA

Benning Power Electronics, Inc.

Service Helpdesk for Traction Chargers

tel

+1 888 296 0292

USA

Benning Power Electronics, Inc.

Technical Support Hotline

tel

+1 800 910 3601

mobile

+1 469 271 6510

USA

Benning Power Electronics, Inc.

Shawn Bowling

[Service Manager]

tel

+1 214 553 1444 301

mobile

+1 469 974 4974

USA

Benning Power Electronics, Inc.

Hans E. Jensen

[Regional Sales Manager - Industrial/Telecom]

mobile

+1 413 588 6365

USA

Benning Power Electronics, Inc.

Steven Smith

[Service-Technician]

mobile

+1 469 562 2778

USA

Benning Power Electronics, Inc.

Frank Warfield

[Technical Support]

tel

+1 214 553 1444 215

mobile

+1 972 977 1252

USA

Benning Power Electronics, Inc.

Israel Velasco

[Sales Director - Mexico]

mobile

+52 1 55 693 159 82

USA

Benning Power Electronics, Inc.

Steven Moore

[Material Logistics Manager]

tel

+1 214 553 1444 245

USA

Benning Power Electronics, Inc.

Janet Monk

[Support staff-Service coordinator / Scheduling]

mobile

+1 972 595 4829

USA

Benning Power Electronics, Inc.

Eric McDonald

[Technical Director/Innovation]

tel

+1 214 553 1444 229

mobile

+1 214 755 7233

USA

Benning Power Electronics, Inc.

Teddy Kostov

[Director of Operation]

tel

+1 214 553 1444 285

USA

Benning Power Electronics, Inc.

Kiran Karuman

[President/CEO]

USA

Benning Power Electronics, Inc.

Jose Hernandez

[Engineering Projects Director]

tel

+1 214 553 1444 237

mobile

+1 469 344 1951

USA

Benning Power Electronics, Inc.

Kim Groves

[Engineering/Inside Sales]

tel

+1 214 553 1444 221

mobile

+1 972 467 3973

USA

Benning Power Electronics, Inc.

Bob Geddie

[Quality Manager/QMS]

tel

+1 214 553 1444 290

mobile

+1 214 793 7211

USA

Benning Power Electronics, Inc.

David Almond

[COO - Service / Telecom]

tel

+1 214 553 1444 233

mobile

+1 214 632 9583

USA

Benning Power Electronics, Inc.

Shawn Bowling

[Service-Manager]

mobile

+1 469 974 4974

USA

Benning Power Electronics, Inc.

David Bearrow

[Technical Support]

tel

+1 214 553 1444 284

mobile

+1 214 908 6502

USA

Benning Power Electronics, Inc.

Anthony Beezel

[Service-Technician]

mobile

+1 972 310 8185

USA

Benning Power Electronics, Inc.

Tina Foster

[Customer Service Manager]

tel

+1 214 553 1444 238

USA

Benning Power Electronics, Inc.

tel

+1 2 14 / 5 53 14 44

address

1220 Presidential Drive
Richardson, Texas 75081
U.S.A.

USA

Benning Power Electronics, Inc.

tel

+1 2 14 / 5 53 14 44

address

1220 Presidential Drive
Richardson, Texas 75081
U.S.A.

USA

Benning Power Electronics, Inc.

tel

+1 2 14 / 5 53 14 44

address

1220 Presidential Drive
Richardson, Texas 75081
U.S.A.

USA

Benning Power Electronics, Inc.

tel

+1 2 14 / 5 53 14 44

address

1220 Presidential Drive
Richardson, Texas 75081
U.S.A.