BENNING PV Inverter: TLS Range

Modern Energy Production and Storage

Modern Energy Production and Storage

BENNING PV Inverter: TLS 5.1

Single Phase Inverter Characteristics

  • 2 MPP trackers
  • Plug & Play installation
  • up to 5,700 Wp recommended DC power
  • relay contact for self-consumption optimization
  • integrated data logger and web server
PV Inverter TLS 5.1
PV Inverter TLS 5.1
DC Input: BENNING PV Inverter TLS 5.1
Recommended DC power (+15 % acc. ISE) 5700 W
Maximum input voltage 850 V
Minimum input voltage/Start input voltage 180 V / 200 V
Minimum input voltage * 180 V
MPP voltage range 250 - 720 V
Rated input voltage 680 V
Maximum current per input (A/B) ** 12 A
Maximum short circuit current per input 16 A
Start feeding-in at 20 W
Number of independent MPP inputs 2
Strings per MPP input 1
DC terminal type SUNCLIX
DC Overvoltage category III
AC Output: BENNING PV Inverter TLS 5.1
Rated output power (230 V / 50 Hz, cos(φ)=1) 4600 W
Maximum apparent AC power 4600 VA
AC connection L / N / PE
AC nominal output voltage range 230 V +/-20 %
Power factor range, adjustable cos(φ) 0,9 ind. … 1 … 0,9 kap.
Operating range at nominal frequency 50 Hz 50 Hz / 47,5 Hz - 51,5 Hz
Maximum output current 22 A
Maximum short circuit current 22 A
Maximum permitted fusing Circuit breaker 16 A (TLS 5.1 - 32 A), characteristic B
Distortion factor at cos(φ) = 1 < 3 %
Self-consumption at night < 2 W
AC Overvoltage category III
Efficiency BENNING PV Inverter TLS 5.1
Maximum efficiency 97,8 %
European efficiency 97,2 %
Protection and protective devices: BENNING PV Inverter TLS 5.1
Topology transformerless
Protection class I
Earth fault detection integrated
Residual current monitoring integrated, sensitive to universal current
Overload behaviour operating point adjustment
Overtemperature behaviour operating point adjustment
Input isolator integrated
Overvoltage protection-input integrated, type 3 as per EN61643-11
Overvoltage protection-output integrated, type 3 as per EN61643-11
Automatic disconnection device as per VDE 0126-1-1
Environmental conditions BENNING PV Inverter TLS 5.1
Ingress protection IP 65
Cooling concept fan-less
Operating temperature range -20°C – 60°C
Maximum ambient temperature at rated power 45°C
Climatic category 4K4H according to IEC 721-3-4 ***
Maximum operating altitude 2000 m above sea level
Noise emission ≤ 50 dB(A)
Standards and approvals BENNING PV Inverter TLS 5.1
EMC emission EN 61000-6-3: 2007
EMC immunity EN 61000-6-2: 2005
Equipment safety EN 62109-1, -2
Grid compliance VDE-AR-N 4105
General Data: BENNING PV Inverter TLS 5.1
Dimensions in mm (W x H x D) 360 x 506 x 190 (without plugs)
Weight (approx.) 26 kg
Features BENNING PV Inverter TLS 5.1
Display liquid crystal display, 128 x 64 pixel
Communication interfaces (internal) RS 485, USB, Ethernet, solar radiation, S0 as per DIN EN 62053-31 class B
Data storage 24 hours: 5-min values
30 days: hourly values
20 years: daily values
Relay contact 2 x potential-free contact

*) This value is valid if one input has exceeded the start input voltage.
**) It is permitted to exceed this limit as long as the maximum short circuit current is not exceeded.
***) The device is designed for an outdoor use. Direct sunlight and precipitation (rain, snow hail) hast to be avoided on site.